Follow us: |
Physiologically Anchored Deep Learning Using Paired Sinus Rhythm and Premature Ventricular Contraction Electrocardiograms for Ventricular Ectopic Origin Localization
1Department of Cardiology, Health Sciences University, Kocaeli City Hospital, Kocaeli, Türkiye
2Biomedical Science, Faculty of Life Sciences & Medicine, King’s College London, London, United Kingdom
3Department of Cardiology, Medical Park Florya Hospital, İstinye University, İstanbul, Türkiye
4Department of Radiology, Machine and Hybrid Intelligence Lab, Northwestern University, Chicago, IL, USA
5Department of Cardiology, Health Sciences University, Sultan Abdulhamid Han Training and Research Hospital, İstanbul, Türkiye
Anatol J Cardiol - PubMed ID: 43075973 DOI: 10.14744/AnatolJCardiol.2026.6789
Full Text PDF

Abstract

Background: Accurate non-invasive localization of premature ventricular contractions (PVCs) is important for preprocedural planning before catheter ablation. Most artificial intelligence–based electrocardiography (ECG) models evaluate ectopic beats without incorporating patient-specific baseline ventricular conduction patterns. This study aimed to develop and evaluate a patient-referenced, QRS-centered deep learning framework integrating paired sinus rhythm and PVC 12-lead ECG recordings for binary localization of ventricular ectopic origin and to assess the incremental value of sinus rhythm information compared with PVC-only input.

Methods: This retrospective, single-center diagnostic accuracy study included 270 patients with paired sinus rhythm and PVC ECG recordings and procedurally confirmed ventricular ectopic origin. Raw ECG signals were segmented using annotated QRS boundaries and aligned using a QRS-centered strategy. Three input strategies were evaluated: paired PVC + sinus rhythm, PVC-only, and sinus rhythm-only. A 1-dimensional residual convolutional neural network (CNN) (1D ResNet) and a 2-dimensional time-domain CNN (2D time-domain CNN) were trained directly on raw ECG waveforms, with late-fusion probability averaging used for ensemble predictions. Performance was assessed using 5-fold patient-level cross-validation. The primary endpoint was the area under the receiver operating characteristic curve (AUROC).

Results: For paired PVC + sinus rhythm input, pooled AUROC values were 0.753 for the 1D ResNet, 0.743 for the 2D time-domain CNN, and 0.762 for the late-fusion ensemble, with no statistically significant differences among architectures. In the cross-input comparison, ensemble AUROC was 0.762 for paired PVC + sinus rhythm, 0.731 for PVC-only, and 0.551 for sinus rhythm-only input. Paired PVC + sinus rhythm significantly outperformed PVC-only input (DeLong P = .0313), whereas sinus rhythm alone showed limited discrimination.

Conclusion: Patient-specific sinus rhythm information provided incremental discriminatory value when combined with PVC morphology for binary left ventricular–right ventricular (LV–RV) localization, while sinus rhythm alone had limited discriminatory value. These findings provide proof-of-concept evidence supporting paired sinus rhythm–PVC modeling as a physiologically informed approach to ventricular ectopic localization. External validation and comparison with established ECG-based localization criteria are required before clinical implementation.