Comprehensive echocardiographic imaging of atrioventricular valves in children with atrioventricular septal defect: Accuracy of 2D and 3D imaging and reasons for disagreement [Anatol J Cardiol]
Anatol J Cardiol. 2019; 21(4): 214-221 | DOI: 10.14744/AnatolJCardiol.2019.49376  

Comprehensive echocardiographic imaging of atrioventricular valves in children with atrioventricular septal defect: Accuracy of 2D and 3D imaging and reasons for disagreement

Nina Hakacova1, Thomas Higgins1, Torsten Malm1, Per Wierup1, Charles Maynard2, Jens Ramgren Johansson1
1Children´s Heart Centre, Skane University Hospital; Lund-Sweden
2Department of Health Services, University of Washington Seattle; Washington-USA

Objective: To compare the accuracy and reasons for disagreement of two-dimensional (2D) and three-dimensional (3D) echocardiography findings in the assessment of the atrioventricular valve complex in patients with atrioventricular septal defect.
Methods: A total of 20 children (mean age 8 months) with atrioventricular septal defect were enrolled prospectively into this study. The accuracy of and the reasons for disagreement in the assessment of the atrioventricular valve features were analyzed between 2D and 3D echocardiography and surgical findings.
Results: We found that in assessing the Rastelli type and the extension of the inferior leaflet into the right ventricle, 3D echocardiography was more accurate compared to 2D echocardiography. In all other features, 2D and 3D echocardiography showed similar accuracy. A significant reason for inaccuracy by both echo modalities was that the technique itself could not visualize the feature, although the image quality was considered to be adequate. In most cases, where it was not possible to visualize the atrioventricular feature by 2D, it was possible by 3D, and vice versa.
Conclusion: The accuracy of 2D and 3D echocardiography and understanding the potential reasons for disagreements in assessing the atrioventricular valve complex with 2D and 3D can guide the use of those two techniques when combining them in the clinical practice.

Keywords: 3D echocardiography, 2D echocardiography, atrioventricular septal defect, accuracy, congenital heart disease


Nina Hakacova, Thomas Higgins, Torsten Malm, Per Wierup, Charles Maynard, Jens Ramgren Johansson. Comprehensive echocardiographic imaging of atrioventricular valves in children with atrioventricular septal defect: Accuracy of 2D and 3D imaging and reasons for disagreement. Anatol J Cardiol. 2019; 21(4): 214-221

Corresponding Author: Nina Hakacova, Sweden


TOOLS
Full Text PDF
Print
Download citation
RIS
EndNote
BibTex
Medlars
Procite
Reference Manager
Share with email
Share
Send email to author

Similar articles
PubMed
Google Scholar




 
 
KARE Publishing | Copyright © 2018 Turkish Society of Cardiology